Source code for brainaccess.core.eeg_channel

"""Channel IDs of the values in a data chunk.

A stream delivers its data as one array per channel. Each constant here is a
channel ID. Enable a channel with
:meth:`~brainaccess.core.eeg_manager.EEGManager.set_channel_enabled`, and find
its position in the chunk the callback receives with
:meth:`~brainaccess.core.eeg_manager.EEGManager.get_channel_index`. Channels that
exist once per electrode (or per axis) use consecutive IDs: add the zero-based
electrode (or axis) number to the base ID.

=========================  =========================  ========================================
Channel ID                 Array dtype                Unit
=========================  =========================  ========================================
``SAMPLE_NUMBER``          ``uint64``                 samples
``ELECTRODE_MEASUREMENT``  ``float64``                µV (kOhm in an impedance mode)
``ELECTRODE_CONTACT``      ``uint8``                  0 or 1
``DIGITAL_INPUT``          ``uint8``                  0 or 1
``ACCELEROMETER``          ``float32``                m/s²
``GYROSCOPE``              ``float32``                deg/s
``STREAMING``              ``uint8``                  0 or 1
=========================  =========================  ========================================

Use :meth:`~brainaccess.core.eeg_manager.EEGManager.get_stream_channel_data_types`
to read the dtypes of the running stream.

Examples
--------
Find the accelerometer axes and the first electrode in a chunk:

.. code-block:: python

    from brainaccess.core import eeg_channel

    x = manager.get_channel_index(eeg_channel.ACCELEROMETER + 0)
    y = manager.get_channel_index(eeg_channel.ACCELEROMETER + 1)
    z = manager.get_channel_index(eeg_channel.ACCELEROMETER + 2)
    first_electrode = manager.get_channel_index(eeg_channel.ELECTRODE_MEASUREMENT + 0)
"""

#: Number of each sample, counted from 0 at the start of the stream. In an
#: impedance mode it counts ADC samples, so it advances by a whole sweep of the
#: active electrodes between impedance estimates.
[docs] SAMPLE_NUMBER = 0
#: Electrode signal in µV, or the electrode impedance in kOhm in an impedance #: mode. One channel per electrode: ``ELECTRODE_MEASUREMENT + n``.
[docs] ELECTRODE_MEASUREMENT = 1
#: Contact of the positive (P) contact of a bipolar electrode with the skin. #: Reserved for bipolar headsets; no current BrainAccess headset provides it.
[docs] ELECTRODE_CONTACT_P = 513
#: Whether the electrode is in contact with the skin (1 = in contact; for an #: electrode with P and N contacts, both must touch). Enabling it makes the #: headset measure the electrode too, since contact can only be detected on a #: measured electrode. One channel per electrode: ``ELECTRODE_CONTACT + n``.
[docs] ELECTRODE_CONTACT = 1025
#: Contact of the negative (N) contact of a bipolar electrode with the skin. #: Reserved for bipolar headsets; no current BrainAccess headset provides it.
[docs] ELECTRODE_CONTACT_N = 1537
#: Debug feature: standard BrainAccess headsets do not provide a digital input; #: on them the channel is always 0. Requires headset firmware 3.8.1 or newer. #: Where available it holds the input level (0 or 1) of each sample, and 0 in rows #: filled in for lost samples.
[docs] DIGITAL_INPUT = 2049
#: Gyroscope in deg/s. Three channels, one per axis: ``GYROSCOPE + 0`` to #: ``GYROSCOPE + 2`` (x, y, z).
[docs] GYROSCOPE = 2497
#: Accelerometer in m/s². Three channels, one per axis: ``ACCELEROMETER + 0`` to #: ``ACCELEROMETER + 2`` (x, y, z).
[docs] ACCELEROMETER = 2561
#: 1 for a row that holds a sample received from the headset, 0 for a row the #: library filled in for a sample that was lost.
[docs] STREAMING = 2625